"resourceType" : "ValueSet",
"id" : "vs-mii-icu-code-observation-beatmung-loinc",
"text" : {
"status" : "empty",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">No human-readable text provided in this case.</div>"
},
"url" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/Code-Observation-Beatmung-LOINC",
"version" : "1.0.0",
"name" : "VS_MII_ICU_Code_Observation_Beatmung_LOINC",
"title" : "VS MII ICU Code Observation Beatmung [LOINC]",
"status" : "active",
"experimental" : false,
"date" : "2022-01-06",
"publisher" : "https://www.medizininformatik-initiative.de",
"description" : "Dieses ValueSet enthält Codes für die im Kontext einer Beatmung eingestellten oder gemessenen Parametern.",
"compose" : {
"include" : [
{
"system" : "http://loinc.org",
"concept" : [
{
"code" : "50984-4",
"display" : "Horowitz index in Arterial blood"
},
{
"code" : "33438-3",
"display" : "Breath rate mechanical --on ventilator"
},
{
"code" : "19839-0",
"display" : "Breath rate spontaneous --on ventilator"
},
{
"code" : "19840-8",
"display" : "Breath rate spontaneous and mechanical --on ventilator"
},
{
"code" : "76334-2",
"display" : "Inspiratory time setting Ventilator"
},
{
"code" : "76187-4",
"display" : "Expiratory hold time setting Ventilator"
},
{
"code" : "75931-6",
"display" : "Inspiration/Expiration time Ratio"
},
{
"code" : "20112-9",
"display" : "Tidal volume setting Ventilator"
},
{
"code" : "76222-9",
"display" : "Tidal volume Ventilator --on ventilator"
},
{
"code" : "20116-0",
"display" : "Tidal volume.spontaneous --on ventilator"
},
{
"code" : "76009-0",
"display" : "Inspired minute Volume during Mechanical ventilation"
},
{
"code" : "20118-6",
"display" : "Tidal volume.spontaneous+mechanical --on ventilator"
},
{
"code" : "76190-8",
"display" : "High pressure hold time setting Ventilator"
},
{
"code" : "76229-4",
"display" : "Low pressure hold time setting Ventilator"
},
{
"code" : "76275-7",
"display" : "Inspiratory flow setting Ventilator"
},
{
"code" : "60794-5",
"display" : "Inspiratory gas flow Respiratory system airway --on ventilator"
},
{
"code" : "60792-9",
"display" : "Expiratory gas flow Respiratory system airway --on ventilator"
},
{
"code" : "19994-3",
"display" : "Oxygen/Total gas setting [Volume Fraction] Ventilator"
},
{
"code" : "71835-3",
"display" : "Oxygen/Gas total [Pure volume fraction] Inhaled gas"
},
{
"code" : "3147-6",
"display" : "Oxygen [Partial pressure] in Exhaled gas"
},
{
"code" : "76530-5",
"display" : "Mean pressure Respiratory system airway --on ventilator"
},
{
"code" : "76531-3",
"display" : "Pressure.max Respiratory system airway --on ventilator"
},
{
"code" : "60827-3",
"display" : "Dynamic lung compliance"
},
{
"code" : "76248-4",
"display" : "PEEP Respiratory system --on ventilator"
},
{
"code" : "76154-4",
"display" : "Airway pressure delta --on ventilator"
},
{
"code" : "20056-8",
"display" : "Airway pressure --at mean expiratory flow on ventilator"
},
{
"code" : "20060-0",
"display" : "Airway pressure --at zero inspiratory flow on ventilator"
},
{
"code" : "19891-1",
"display" : "Carbon dioxide [Partial pressure] in Exhaled gas --at end expiration"
},
{
"code" : "20079-0",
"display" : "Pressure support setting Ventilator"
}
]
}
]
}
}